SALICRU 698RQ000002 The Salicru SLC TWIN RT2 series models are Uninterruptible Power Supply Systems…
SALICRU 698RQ000002 The Salicru SLC TWIN RT2 series models are Uninterruptible Power Supply Systems (UPS/UPS) with the maximum electrical protection features for critical server environments. The dual tower/rack format allows physical adaptability to any location, which together with the built-in PDU strip makes it as easy as possible to connect the loads to be protected. Likewise, the unity output power factor (VA=W) increases the power density delivered and reduces the space required for the installation of the UPS/UPS. The LCD screen is adjustable according to the chosen mounting format for easier handling. As for serial communications, they have USB, RS-232 and relay interfaces, as well as an intelligent slot to optionally house an SNMP card, MODBUS or potential-free contacts. Software packages are also available for monitoring and management, local or virtual, of protected computers. For applications requiring extended backup backup, additional battery modules and/or extra charger solutions can be installed. And for applications that require redundant protection or increase power needs, there is the option of connecting up to 3 devices in parallel.
Specifications
AC Output Type | C13 coupler, C19 coupler, Terminal |
Number of AC outlets | 6 AC outlets |
USB port | Yeah |
Serial interface | Yeah |
Serial interface type | RS-232 |
Port - RS-232 | 1 |
parallel port | 1 |
Emergency shutdown device | Yeah |
Connector | Terminal |
SmartSlot | Yeah |
Power distribution port | Yeah |
Broad | 438mm |
Depth | 600mm |
Height | 88mm |
Weight | 69kg |
Operating temperature range | 0 - 40°C |
Relative operating humidity | 0 - 95% |
Operating altitude | 0 - 2400m |
Battery Type | Lead-Calcium (Pb-Ca) |
Cold start | Yeah |
Recharge time (90%) | 9am |
Type of load | Constant current/Constant voltage |
Supported operating systems | Windows, Linux, Mac |
Form factor | Rack/Tower Mount or Rack/Tower Mount |
Product color | Black |
Cooling type | Asset |
LED indicators | Yeah |
Screen | LCD |
Security | EN 62040-1 |
Rack capacity | 4U |
Certification | EN 62040-2 |
UPS Topology | Double conversion (online) |
Output power capacity (VA) | 4000VA |
Output power | 4000W |
Operating input voltage (min) | 110V |
Operating input voltage (max) | 300V |
Input frequency | 50/60Hz |
Output operating voltage (min) | 208V |
Output operating voltage (max) | 240V |
emergency shutdown | Yeah |
Overload capacity (10 minutes) | 110% |
Overload capacity (1 minute) | 130% |
Input Current Total Harmonic Distortion (THD) | 4% |
Total Harmonic Distortion (TDH) (line load) | 1% |
Total Harmonic Distortion (TDH) (non-linear load) | 4% |
Noise level | 60dB |
Power protection functions | Low current, Low voltage |
Network synchronization | 4Hz |
Synchronization without network | 0.1Hz |
Output frequency | 50/60Hz |
Automatic Voltage Regulation (AVR) | Yeah |
power factor | 1 |
Plug circuit breaker | Yeah |