Golmar RPT-01 zone repeater

Golmar
golmar-10930002
Up to a maximum of 48 zone repeaters. Coverage range of up to 500m to the Control Unit. Each zone repeater is capable of controlling up to 64 room and/or bathroom transmitters. It controls all the devices it has associated to ensure that they work correctly. In the event of a fault in any of them, the repeater will transmit a fault alarm. Requires 220V power.
  • Out-of-Stock
Golmar RPT-01 zone repeater
Quantity

Golmar RPT-01 zone repeater. Up to a maximum of 48 zone repeaters. Coverage range of up to 500m to the Control Unit. Each zone repeater is capable of controlling up to 64 room and/or bathroom transmitters. It controls all the devices it has associated to ensure that they work correctly. In the event of a fault in any of them, the repeater will transmit a fault alarm. Requires 220V power.

Features

  • RPT-01 zone repeaters.
  • The Wireless Network is made up of zone repeaters.
  • One is usually located in each plant or area to be covered, with distances not exceeding 50m.
  • The zone repeaters are in charge of relaying the signal from the room transmitters to the CH-01 Control Units.
  • The system supports up to a maximum of 48 zone repeaters, each offering a coverage range of up to 500m to the Control Unit and 50 meters to the room or bathroom transmitters.
  • Each zone repeater is capable of controlling up to 64 room and/or bathroom transmitters.
  • The zone repeater is in charge of controlling all the associated devices to ensure that they work correctly.
  • In the event of a fault in any of them, the repeater will transmit a fault alarm with precise indication of the device that is not responding.
  • The zone processor receives all the alarms from the associated transmitters and is responsible for forwarding them to the central unit of the system wirelessly.
  • It only needs to be fed to the electrical current to function, once it has been properly programmed.
  • Requires factory programming PROG-01.
  • It incorporates the possibility of mounting safety batteries inside so that the system continues to function in the event of a power failure, for a maximum period of 30 minutes.

Other features

  • Hospitals: Control units
  • Hospitals: Sources and servers
  • Technology: Wireless
  • Technology: No audio

Downloads

golmar-10930002

Summary

0

star_border star_border star_border star_border star_border

(0 Reviews)

Select a row below to filter reviews.

Only users who already bought the product can add review.

No customer reviews for the moment.

You might also like

THEME OPTIONS

Panel Tool

Yes No